What was found
INSPECTION TYPE:C RIGHT WING L/E LWR COMPT STA XORP562 FOUND UPPER STRAP CRACK AS MARKED. AS ABOVE STATED AREA, STRINGER SPLICE REMOVED PER EN1060-07. DAMAGED STRINGER TRIMMED PER EN1060-07. HFEC CUTOUT FOUND SATISFACTORY. NEW STRINGER & SPLICE FAB PER EN1060-07. NEW FAB STRINGER & SPLICE DRILLED HOLES PER EN106 0-07. NEW PARTS OK TO INSTALL. RIGHT WING L/E LWR COMPT STA XORS 562 REPAIR PARTS INSTALLED AS PER EN1060-07, FOUND SATISFACTORY.