What was found
INSPECTION TYPE:C CTR CARGO, STA 1540 LONGERON L45 FOUND WITH CORROSION AS MARKED. THE A/M LONGERON L45 STA 1540 AREA OPENED UP FOR REPAIR PER SRM 51-31-0 1 V2 R38. S/BUSHING REMOVED PER EN 1148-07 FOR EXISTING REPAIR ON L45. LONGERON & SPLICE FAB PER SRM 53-10-00 V1 F2 R38. FPI CUT OUT ON FAB LONGERON & SPLICE FOUND NO CRACK EVIDENT. S/BUSHING FAB PER EN1148-07. OK TO INSTALL. REPAIRED S/BUSHING INSTALLED PER EN1148-07, FOUND SATIS.