What was found
INSPECTION TYPE:C RH MLG W/W, FUSELAGE SIDE DOOR CUTOUT AT STA 1450 RBL 105 01 EA WEB ON O/B EDGE FOUND CHAFFED AS MARKED. CHAFE MARK REMOVED, FOUND EXCEED LIMIT ORIG THK 0.040" MATL REMOVED 0.032" REMAIN THK 0.008" PER SRM 53-00-01 FIG3 VOLIR38. DAMAGED WHEN REMOVED PER SRM51 -35-01VOLIIR38. FAB NEW WEB PER BOEING DWG ANB7180REVAF MATL 7075-0.04 0". HEAT TREAT PER DPS7.00-1 AND HRB82.4 PER DPS1.05-3. HOLES PICKUP AND PROTECTED PER SRM 51-35-01 AND 51-21-01VIIR38. INSTALL PER SRM 51-35-01 VOL IIR38.