What was found
INSPECTION TYPE:C DOOR 3 CROWN AREA, AT STA 1256 TO STA 1273 LONG 1 LT INTERCOSTAL BOTH FACES FOUND CORROSION. CORROSION REMOVED PER SRM 51-21-01 VOLIIR38 ORI THK 0.032", MAT'L REMOVED 0.020", MAT'L REMAINED 0.012" FOUND OUT OF LIMIT PER SRM 53-00-01 FIG1AVOLIR38. INTERCOSTAL REMOVED PER SRM 51-35-01 VOLIIR38. NEW INTERCOASTAL FAB PER BOEING DWG AEA0202REVK. HEAT TREAT PER DPS7.00-1 AND HARDNESS VALUE 15T88.5 PER DPS1.05-3. INTERCOSTAL INSTALL PER SRM 51-35-01 VOL IIR38.