What was found
INSPECTION TYPE:C DOOR 3 CROWN AREA, AT STA 1256 TO STA 1273 LONG 1 RT INTERCOSTAL FACE FOUND CORROSION. CORROSION REMOVED PER SRM 51-21-01 VOL IIR38 ORI THK 0.032" MATL REMOVED 0.023" MATL REMAIN 0.009" FOUND OUT OF LIMIT PER SRM 53-00-01 FIG1AVOLIR38. INTERCOSTAL REMOVED PER SRM 51-35-01VOL IIR38. NEW INTERCOSTAL FAB PER BOEING DWG AEA0202REVK. HEAT TREATED PER DPS7.00-1 AND HARD VALUE 15T88.5 PER DPS1 05-3. HOLES PICK UP, PROTECTED AND PAINT. INSTALLED PER SRM 51-35-01 VOLIIR38.