What was found
INSPECTION TYPE:C LEFT WING I/B FLAP I/B ACTUATOR ENCLOSURE, UPPER AFT LARGE ROLLER BEARING MO MOUNTING FOUND CORRODED. I/B & O/B BUSHINGS MOUNT ELONG HOLE EXCEED LIMIT. I/B HOLE MATL REMOVED 0.0 06" O/B HOLE MATL REMOVED 0.015". MAX ALLOW DIA 1.000". FPE C/O DPS4.707 REV AW, NO CORROSION. REWORK HOLES DIA & THK EVAL & FOUND ACCEPTABLE EN1265-0 7. BUSHING 2EA FAB EN1265-07. MPI C/O ON FAB BUSHINGS, FOUND NO CRACK. BUSHINGS INSTALLED PER EN1265-07.