What was found
INSPECTION TYPE:C HORIZ STAB, BARREL NUT BORE RIGHT NR 23 FOUND CORROSION. CORROSION REMOVED SRM 51-21-01 VII R38. BOTTOM-BORED THRU BORE REAMED TO 1.067" DIA. REMAINING BLENDOUT 0.010" DEEP EXCEED EO LIMITS. 10X MAG DVI C/O NO CORROSION. BORE BLEND OUT RADIUSED, SMOOTHEN & PROTECTED SRM 51-21-01 VII R38. REPAIR BUCKET BUSHING FAB, PROTECTED & INSTALLED PER EO FIG 5. REPAIR C/O AT BARREL NUT BORE NR 23 RIGHT IS ACCEPTABLE IAW EN1204-07.