What was found
INSPECTION TYPE:C HORZ STAB BARREL NUT BORE NR 21 RIGHT FOUND WITH CORROSION. CORROSION REMOVED SRM 51-21-01 VII R38. BOTTOM-SURF CLEANED, BORE REAMED TO 1.067" REMAIN BLENDOUT 0.015" DEEP EXCEED EO LIMITS. 10X MAG DVI C/O NO CORROSION. BORE BLENDOUT & BOTTOM PERI RADIUSED, SMOOTHEN & PROTECTED SRM 51-21-01 VII R38. REPAIR SLEEVE BUSHING FAB, PROTECTED & INSTALLED AS PER EO FIG 5. REPAIR C/O AT BARREL NUT BORE IS ACCEPTABLE IAW EN1221-07.