What was found
INSPECTION TYPE:N/A ATB - LEFT I/B FLAP INDICATION 20 DEGREES WITH STICKER SHAKER. EMERGENCY DECLARED TO HAVE EQUIPMENT STANDING BY PRECAUTIONARY. FOUND LEFT INBOARD FLAP POSITION XMT INOP. REPLACED PER MM 27-54-24-4, RAN SYSTEM THROUGH FULL OPS CHECK. OK FOR CONTINUED SERVICE. ACCOMPLISHED CAT IIIB TEST PER MM 24-54-00, SYSTEM TEST OK.