What was found
INSPECTION TYPE:C AFT FUSELAGE, AFT PRESSURE BULKHEAD, AFT FACE STA 2007, RBL10', UPPER PORTION OF T CHORD FOUND WITH CRACK AT EDGE AS MARKED. AFT FUSELAGE, AFT PRESSURE BULKHEAD, AFT FACE STA 2007 RBL UPP PORTION REMOVED FOR ACCESS REPAIR PER SRM 51-21-01V.R.38. THE FOLLOWING ITEMS WERE FAB(A) T CHORD REPAIR SECTION PER DWG NR AJC7050. SPLICE ANGLES FAB PER SRM 53-00-01F9.V1.R38. FILLERS WEB SUPT ANGLES FAB PER SRM 53-00-01 .F9.V9.R38. RE-ASSEMBLE C/OUT AFT FX, AFT PRESS BULKHEAD STA 2007, SATIS.