What was found
INSPECTION TYPE:C RIGHT WING UPPER SURFACE FIXED L/E STRUCTURE FOUND DEEP DENT AT STA XORS 593 AREA. RIGHT WING L/E COMPT RIBS 4EA REMOVED. RIGHT WING L/E DAMAGED SKIN TRIMMED PER EN12 63-07. HFEC INSP CUT OUT ON TRIMMED OFF AREA, FOUND NO CRACK. REPAIR SKIN & DOUBLER FAB PER EN1263-07. REPAIR SKIN HEAT TREATED, FASTENER HOLES PICKED UP & REWORKED, REPROTECTED & PAINTED. REPAIR PARTS & SKIN INSTALLED. REWORK AREA PAINTED.