What was found
INSPECTION TYPE:C RIGHT WING - WING T/E INBOARD ISLANDS UPPER SURFACE FOUND CRACK ON FWD SIDE APPROX AT XORS 455 AS MARKED. HFEC INSP C/O DAC NDTSPM REV13 06-10-01.001 & FOUND CRACK OF .375 INCH. FASTENERS AT AFFECTED AREA REMOVED FOR ACCESS SRM 51-31-01VII R38. CRACKED AT TRIM OUT SRM 57-10-00 FIG 34 VI R38. HFEC INSP C/O DAC NDTSPM R13 06-10- 01.001 ON TRIM OUT AREA. NO CRACK FOUND. NEW FILLER & DOUBLER FAB. NEW FILLER & DOUBLER INSTALLED SRM 51-35-01VII R38 & SRM 51-33-01VII R38.