What was found
INSPECTION TYPE:C EXISTING REPAIR FOUND ON RIGHT DROOP ASSY UPPER SURFACE O/B SIDE AS MARKED. EXISTING REPAIR REMOVED AS PER SRM 51-31-01 V2 R38. REPAIR DOUBLER FABRICATED PER EN1349-07. HFEC INS CARRIED OUT PER DAC NDTSPM R13 06-10-01.001 FOUND CRACK APPROX 4 1/8" & CRACK END AS MARKED. DOUBLER HEAT TREATED PER DPS 5.00-2 & HARDNESS VALUES 41.8 PER DPS1.05.5. HOLES ON NEW DOUBLER P/UP PER ADV EN1349-07. DOUBLER INSTALLED PER EN1349-07.