What was found
INSPECTION TYPE:C RT O/B FLAP I/B HINGE (WING MOUNTED) LOWER ATTACHMENT LUG O/B FOUND BORE AND SPOT FACES CORROSION AS MARKED. BORE AND SPOTFACE CORROSION REMOVED, EXCEED LIMIT CMM 57-44-08 PG 602-607 R58. ORG DIA 0.644" THK 0.461" FINAL DIA 0.706" THK 0.435" MATL REMOVED 0.026" MAX ALLOW DIA 0.709" MIN ALLOW THK 0.720". FPI C/O AND FOUND NO CRACK EVIDENT. FLAP PEENING C/O ON REWORKED AREA BSOPM20-11-01R58. BUSHING FAB CMM57-44-08 R58. BUSHING INSTL PER CMM57-44-08R58.