What was found
INSPECTION TYPE:C RT O/B FLAP I/B HINGE (WING MOUNTED) LOWER ATTACHMENT LUG I/B FOUND BORE AND SPOT FACES CORROSION AS MARKED. BORE AND SPOTFACE CORROSION REMOVED, EXCEED LIMIT CMM 57-44-08 PG 602-607 R58 ORG DIA 0.644" THK 0.460" FINAL DIA 0.707" THK 0.441" MATL REMOVED 0.019" MAX ALLOW DIA 0.709" MIN ALLOW THK 0.720". FPI C/O AND FOUND NO CORROSION AND CRACK EVIDENT. FLAP PEENING C/O BSOPM20-11-01 R58. BUSHING FAB CMM57-44-08R58. BUSHING INSTL PER CMM 57-44-08R58.