What was found
INSPECTION TYPE:C CENTER CARGO COMPT AT STATION 1841 IN BETWEEN LONGERON 51 LT TO 51 RT FOUND CORROSION AS MARKED. CTR CARGO COMPT STA 1841 BETWEEN L51 LT - L51 RT CORROSION REMOVED FOUND EXCEEDED LIMITS. REPAIR CHANNEL FAB FROM MAT'L 7075-0 0.080". CHANNEL HEAT TREATED & HARNESS VALUES HRB 82.2 AS PER DPS 1.05-3. REPAIR CHANNEL REPROTECTED. REPAIR CHANNEL PAINTED. REPAIR CHANNEL INSTALLED. PAINT TOUCHED UP ON REWORK AREA.