As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C HORIZ STAB CONSTANT SECTION BARREL NUT BORE LT NR 28 FOUND WITH CORROSION. CORR AT BARREL NUT BORE RMVD PER SRM 51-21-01 VII R38. BOTTOM BORE THRU BORE REAM TO 1.178" DIA. RMN BLEND OUT 0.025" DEEP, EXCEEDED LIMITS. BARREL NUT BORE, BLEND OUT VOID SMOOTHEN & PROTECTED. BUCKET BUSHING FAB, PROTECTED & INSTALLED. REPAIR C/O AT BARREL NUT BORE NR 28 LT IS ACCEPTABLE AS PER EN 1519-07.