What was found
INSPECTION TYPE:C RIGHT WING L/E COMPARTMENT AT STA XORS 568 APPROX FOUND UPPER STIFFENER CRACKED AS MARKED. CRACKED STIFFENER & ATTACH PARTS REMOVED. NEW STIFFENER FABBED USING MAT'L 7075-0-0.071" PER DOUGLAS DWG ARB3954. STIFFENER HEAT TREATED PER DPS 7.00-1 & HARDNESS VALUES HRB 84.0 PER DPS 1.02-3. NEW STIFFENER HOLES P/UP, REPROTECTED & PAINTED. NEW STIFFENER INSTALLED AS PER SRM 51-33-01 VOL II REV 38 & SRM 51-35-01 VOL II REV 38.