What was found
INSPECTION TYPE:C HORIZONTAL STAB CONSTANT SECTION BARREL NUT BORE LT NR 27 FOUND WITH CORROSION. CORR REPAIR BUCKET BUSHING REMOVED & BARREL NUT BORE SURFACE CLEANED. REMN BLEND OUT 0.020" DEEP, EXCEEDS EO LIMITS PER EO MD11-5510-19409-L. BORE SIZE 1.180" DIA. BARREL NUT BORE, BLEND OUT PERIPHERY SMOOTHEN & PROTECTED. BUCKET BUSHING FAB & PROTECTED. BUCKET BUSHING INSTALL. REPAIR C/O AT BARREL NUT BORE NR 27 LT, ACCEPTABLE PER EN 1456-07.