What was found
INSPECTION TYPE:C RIGHT WING NR 16 SLAT TRACK I/B RIB FITTING SUSPECTED CRACK AS MARKED. HFEC INSP C/OUT FOUND CRACK AS MARKED. RIGHT WING NR 8 EXT & RET CABLES DISCONNECTED. RIGHT WING NR 16 SLAT TRACK DOOR, ATTACHED HARDWARES & ROLLERS & SLAT TRACK REMOVED. RIGHT WING NR 16 SLAT WIRING, CLAMPS & RIB REMOVED. NEW HOLES TRANSFERED ONTO NEW RIB PER DOUGLAS DWG ARB2873. DAMAGE AREA AT WING SKIN & DOUBLER TRIM OFF. HFEC INSP C/OUT ON TRIMMED OFF AREA FOUND.