What was found
INSPECTION TYPE:C CTR CABIN - UNDER FLOOR AREA FUEL TANK TOP SURFACE AT STA 1210, -X103 01EA CORROSION FOUND NEAR FASTENER. CTR CABIN UNDER FLOOR AREA FUEL TANK TOP SURFACE AT STA 1210 -X103 FUEL TANK SCREW AS MARK REMOVED FOR S/M ACCESS. CORROSION ON FUEL TANK TOP SURFACE REMOVED FOUND EXCEEDED LIMIT. FPI & HFEC OPEN HOLE INSP C/OUT ON REWORKED AREA FOUND NO CRACK & NO CORROSION. FLAP PEENING C/ OUT ON REWORKED AREA PER EN1642-07. REWORKED AREA REPROTECTED, PAINT.