What was found
INSPECTION TYPE:C LT I/B FLAP UPPER SURFACE FOUND OIL-CANNING AT 53 INCHES FROM I/B END AND 23" FROM T/E END AS MARKED. DAMAGED PORTION ON LT I/B FLAP UPPER SURFACE TRIM OFF PER SRM 57-10-00 FIG 34 VIR 35. HFEC INSP C/O ON TRIM OFF AREA, FOUND NO CRACK EVIDENT. REPAIR DOUBLER FAB USING 2024T3-0.040 INCH MAT'L PER SRM 57-10-00 FIG34 VIR 35. REPAIR DOUBLER FASTENER HOLES DRILLED, RE-PROTECTED AND PAINTED. NEW DOUBLER INSTALLED PER SRM 51-35-01VIIR 35 AND SRM 57-10-00 FIG 34 VIR 35.