What was found
INSPECTION TYPE:N/A COURIER/SUPERNUMERARY AREA INTERIOR EMERGENCY LIGHT SYSTEM INOP. REMOVED AND REPLACED C/B 28WJ PER AMM 33-26-21 AND ESPM 20-46-10. OPS TEST PER AMM 33-51-00-05. CHECKS GOOD. CLEARS M389086. PLACARD REMOVED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:N/A COURIER/SUPERNUMERARY AREA INTERIOR EMERGENCY LIGHT SYSTEM INOP. REMOVED AND REPLACED C/B 28WJ PER AMM 33-26-21 AND ESPM 20-46-10. OPS TEST PER AMM 33-51-00-05. CHECKS GOOD. CLEARS M389086. PLACARD REMOVED.