What was found
INSPECTION TYPE:N/A ATB - DURING CLIMB LT ENGINE OVERHEAT LIGHT CAME ON. REDUCED POWER, LIGHT WENT OUT. RE-APPLIED POWER, LIGHT CAME BACK ON. REDUCED POWER, RETURNED TO MIA. ACCOMPLISHED 757 FIM 26-11-00 FIG 103A FOUND LEFT ENG HPSOV SENSE LINE AND UNION LEAKING. REMOVED AND REPLACED HP6 SENSE LINE AND UNION REF ITEM 3 OF THIS LP. ACCOMPLISHED AMM 71-00-00-5 TEST 13. OPS AND LEAK CHECK NORMAL.