As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C MEC CABIN FLOORBEAM STA 246 LBL 55 VERTICAL STIFFENER FOUND CRACK (CRACK LENGTH 1 INCH). VERT STIFFENER REPLACED AS PER SRM 53-10-51-2R FIG 201 REPAIR 3 UPS MPI P19867 RAISED FOR REPEAT DVI AT 3000 CYC OR 24 MONTHS, WHICHEVER COMES FIRST.