What was found
INSPECTION TYPE:C2 MAIN CABIN FLOOR PNL CORRODED AT STA 1120 RBL 50. REMOVED FLOOR PNL AT STA 1120 RBL 50 IAW SRM 51-03-00. FABRICATED AND INSTALLED REPAIR FLOOR PNL AT STA 1120 RBL 50 REF EO DC8-5320- 9691C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 MAIN CABIN FLOOR PNL CORRODED AT STA 1120 RBL 50. REMOVED FLOOR PNL AT STA 1120 RBL 50 IAW SRM 51-03-00. FABRICATED AND INSTALLED REPAIR FLOOR PNL AT STA 1120 RBL 50 REF EO DC8-5320- 9691C.