INSPECTION TYPE:C2 LARGE HOLE TORN IN TOP OF INTERCOSTAL AT STA 1276 AND L33R. FABRICATED AND REPLACED INTERCOSTAL AT FS 1276 AND L33R REF DWG 9754949 AND SRM 51-1-20D.