What was found
INSPECTION TYPE:C3 A PIT CARGO COMP FLOORBEAM AT STA 70, LBL 50 IS CORRODED. CUT OUT DAMAGE, FABBED AND INSTALLED REPAIR ANGLE AND FILLER IAW, SRM 51-1-8, 51-3-0, 53-2-0 FIG 1F.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3 A PIT CARGO COMP FLOORBEAM AT STA 70, LBL 50 IS CORRODED. CUT OUT DAMAGE, FABBED AND INSTALLED REPAIR ANGLE AND FILLER IAW, SRM 51-1-8, 51-3-0, 53-2-0 FIG 1F.