What was found
INSPECTION TYPE-C1, FLOOR PANEL NR680 HAS SMALL 3 STIFFENERS CRACKED AS MARKED. FABRICATED AND REPLACED 3EA CRACKED HAT CHANNELS IAW SRM 51-1-4 AND DWG NR 52755898, DWG NR 3619352. ALSO FOUND FLOORBOARD CORRODED OUT OF LIMITS. FABRICATED NEW FLOORBOARD IAW SRM 51-1-4, DWG NR 52755898, AND DWG NR 3619352.