What was found
INSPECTION TYPE-C1, FLOOR PANEL F87 HAS 3 EA SCREW HOLES CRACKED. REMOVED DAMAGE, FABRICATED AND INSTALLED 2EA. DOUBLERS IAW SRM 53-2-3 FIG 010, AND SRM 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C1, FLOOR PANEL F87 HAS 3 EA SCREW HOLES CRACKED. REMOVED DAMAGE, FABRICATED AND INSTALLED 2EA. DOUBLERS IAW SRM 53-2-3 FIG 010, AND SRM 51-1-21.