What was found
INSPECTION TYPE-C1, MAIN CARGO DOOR UPPER FRAME CENTER DOOR JAM HAS A DOUBLE DRILLED HOLE AT STA 220 & 6L. CUTOUT DAMAGE IAW SRM 53-02-00, FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-02-00,51-1-20D, AND 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE-C1, MAIN CARGO DOOR UPPER FRAME CENTER DOOR JAM HAS A DOUBLE DRILLED HOLE AT STA 220 & 6L. CUTOUT DAMAGE IAW SRM 53-02-00, FABRICATED AND INSTALLED REPAIR DOUBLER IAW SRM 53-02-00,51-1-20D, AND 51-1-21.