What was found
INSPECTION TYPE:SP COMPLY WITH ATTACHED WAN NR 1421616 REGARDING CRACK ON L24L. NDT'D NEW CRACKS AND STOP DRILLED, INSTALLED REPAIR DOUBLER AND TAPERED SHIMS IAW SRM, EA 008-10-01-A1544, 51-1-20D, 51-1-8, UPS EO M-5100-27 80-E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SP COMPLY WITH ATTACHED WAN NR 1421616 REGARDING CRACK ON L24L. NDT'D NEW CRACKS AND STOP DRILLED, INSTALLED REPAIR DOUBLER AND TAPERED SHIMS IAW SRM, EA 008-10-01-A1544, 51-1-20D, 51-1-8, UPS EO M-5100-27 80-E.