What was found
INSPECTION TYPE:SP WHILE WORKING NR 164443 FOUND WEB TO BE CRACKED AT PIT TORQUE BOX AREA STA 1390. REMOVED DAMAGED WEB AND INSTALLED FABRICATED WEB SECTION IAW SRM, 51-1-21, 51-1-8, FABBED PER DWG 5616674.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SP WHILE WORKING NR 164443 FOUND WEB TO BE CRACKED AT PIT TORQUE BOX AREA STA 1390. REMOVED DAMAGED WEB AND INSTALLED FABRICATED WEB SECTION IAW SRM, 51-1-21, 51-1-8, FABBED PER DWG 5616674.