What was found
INSPECTION TYPE:SV REPAIR SEQUENCE 803-F1-115 AT STA 1607-1613 L22-23L HAS NO SRM REF. REMOVED REPAIR DOUBLER, CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW DC-8 SRM 53-02-01 FIG 7 SHEET 13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SV REPAIR SEQUENCE 803-F1-115 AT STA 1607-1613 L22-23L HAS NO SRM REF. REMOVED REPAIR DOUBLER, CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW DC-8 SRM 53-02-01 FIG 7 SHEET 13.