What was found
INSPECTION TYPE:SV REPAIR SEQUENCE 803-F1-112 AT STA 1607.5-1625.75 L14-15L HAS NO SRM REF. REMOVED REPAIR DOUBLER, CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-02-01 FIG 7 SHEET 11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SV REPAIR SEQUENCE 803-F1-112 AT STA 1607.5-1625.75 L14-15L HAS NO SRM REF. REMOVED REPAIR DOUBLER, CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-02-01 FIG 7 SHEET 11.