What was found
INSPECTION TYPE:SV REPAIR SEQUENCE 803-F1-02 AT STA 13 L15-16L HAS NO SRM REF. REMOVED REPAIR DOUBLER, FABRICATED AND INSTALLED REPLACEMENT REPAIR DOUBLER IAW UPS EO DC8-5330-31402-A AND FVCI DWG 53-08540-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SV REPAIR SEQUENCE 803-F1-02 AT STA 13 L15-16L HAS NO SRM REF. REMOVED REPAIR DOUBLER, FABRICATED AND INSTALLED REPLACEMENT REPAIR DOUBLER IAW UPS EO DC8-5330-31402-A AND FVCI DWG 53-08540-1.