What was found
INSPECTION TYPE:BCF STA 1160 LT TENSION TIE FRAME WEB 2EA FASTENER HOLE CRACKED MORE THAN 0.050", 6EA FASTENER HOLE CRACKED ABOUT 0.030". REPAIRED CRACKED TENSION TIE FRAME WEB AS PER SRM 53-40-07.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:BCF STA 1160 LT TENSION TIE FRAME WEB 2EA FASTENER HOLE CRACKED MORE THAN 0.050", 6EA FASTENER HOLE CRACKED ABOUT 0.030". REPAIRED CRACKED TENSION TIE FRAME WEB AS PER SRM 53-40-07.