INSPECTION TYPE:C LEFT HORZ STAB NR 23 BARREL NUT HOLE FOUND CORROSION. CORR AT B NUT REMOVED. BORE BOTTOM SURFACE CLEANED & BORE REAM TO 1.067" DIA, REMN BLEND OUT 0.048" DEEP, EXCEEDED LIMITS. 10X MAG-DETAIL VISUA L INSP C/O & FOUND NO CORR EVIDENT. B NUT BORE, BLEND OUT VOIDS & BOTTOM PERIPHERY RADIUS, SMOOTHEN & PROTECTED. REPAIR SLEEVE BUSHING FAB & INSTALLED. REPAIR C/O IS ACCEPTABLE PER EN1726-07.