What was found
INSPECTION TYPE:C LT HORIZ STAB NR 6 BARREL NUT HOLE FOUND CORROSIONS. CORROSION AT B-NUT BORE REMOVED. BORE BOTTOM REMAINING BLEND OUT 0.035" DEEP. BORE REAM TO 0.988" DIA REMAIN BLEND OUT DEPTH 0.030" DEEP FOUND EXCEED LMT PER EO MD11-5510-19409-L. 10X MAG INSP C/O AND FOUND NO CORROSION EVDT. REPAIR SLEEVE BUSHING FAB, PROTECTED AND INSTALLED. C/O FR PRIMER TOUCH UP AT BORE REPAIR AREA. REPAIR C/O IS ACCEPTABLE PER EN 1731-07.