What was found
INSPECTION TYPE:C CENTER CARGO DOOR CUTOUT AFT AREA STA 1790.0 RT L36 FOUND DENT AS MARKED DENT AREA SMOOTHED OUT PER SRM 51-21-01 V.II R35. DENT MARK MEASURED FOUND BEYOND LIMIT PER SRM 53-20-00 FIG 6 V.I R35. HFEC INSP CARRIED OUT PER DAC NDTSPM R.13 06-10-01.001 ON REWORKED AREA AND FOUND NO CRACK EVIDENT. NEW DOUBLERS AND FILLER FAB AND INSTALLED PER SRM 53-50-00 FIG V.I R35 AND SRM 51-31-01 VII R35.