What was found
INSPECTION TYPE:1C RT FIXED LE RIB FITTING IB OF NR 16 SLAT TRACK IS CRACKED. REMOVED AND REPLACED RT FIXED LE RIB FITTING IB OF NR 16 SLAT TRACK PER MD-11 SRM 51-31-01 AND 51-35-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:1C RT FIXED LE RIB FITTING IB OF NR 16 SLAT TRACK IS CRACKED. REMOVED AND REPLACED RT FIXED LE RIB FITTING IB OF NR 16 SLAT TRACK PER MD-11 SRM 51-31-01 AND 51-35-01.