What was found
INSPECTION TYPE:C LEFT WING FIXED L/E COMPT AT STA XORS 500 APPROX FOUND UPPER DOUBLER SUSPECTED CRACK AS MARKED. HFEC INSP C/O PER NDTSPM 06-10-01.001 R13 ON SUSPECTED CRACK AREAS & FOUND APPROX 1/4 CRACK AS MARKED. INBOARD & OUTBOARD RIB AT LEFT FIXED L/E COMPT AT STA XORS 500 AREA REMOVED FOR ACCESS PER SRM 51-31-01 V.II R35. NEW REPAIR DOUBLER 01EA, REPAIR FILLER 01EA & 04EA REPAIR ANGLES FAB & INSTALLED PER SRM 57-10-00 V.I FIG 27 REV 40.