What was found
INSPECTION TYPE:C EMPENNAGE, LT HORIZONTAL STABILIZER FRONT SPAR, TOP OF ACCESS PANEL 331A Z CUTOUT AREA, UPPER SURFACE MOUNTING HOLES FOR L/E PANEL 331BT, FOUND WITH 11 EA ELONGATED MOUNTING HOLES AS MARKED. GANG CHANNEL ASSY REMOVED FOR ACCESS PER SRM 51-35-01 V.II R35. QTY 11EA ELONGATED HOLES REAMED PER EN 1010-08. HFEC OPEN HOLE INSP C/O PER DAC NDTSPM R13 06-10-01.003 ON REWORKED AREA & FOUND NO CRACK EVIDENT. REPAIRED BORE PROTECTED & BUSHING INSTALLED PER EN 1010-08. THIS REPAIR IS TIME LIMITED FOR 24 MONTHS PENDING A DAMAGE TOLERANCE ANALYSIS.