What was found
INSPECTION TYPE:3C CORROSION FOUND ON NR 9 LEFT BARREL NUT BORE HOLE, UPPER HORIZ STAB. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR BUSHING PER EO MD11-5510-19409-M. BUSHING O.D. .945 I.D. .944
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3C CORROSION FOUND ON NR 9 LEFT BARREL NUT BORE HOLE, UPPER HORIZ STAB. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR BUSHING PER EO MD11-5510-19409-M. BUSHING O.D. .945 I.D. .944