What was found
INSPECTION TYPE:C LEFT O/B TRAILING EDGE FLAP I/B WING MOUNTED HINGE AFT LOWER O/B BORE HOLE AND FACE AREA RUSTY AS MARKED. LEFT FWD O/B FLAP I/B HINGE LWR MOUNT O/B BORE & SPOTFACE CORROSION REMOVED & FOUND EXCEED LIMIT PER CMM57-44-08 PG 602-607R.60. FPI C/OUT IAW DACNDTS PMR.13PART08. FOUND NO CRACK & CORROSION EVIDENT. LEFT FWD O/B FLAP I/B HINGE LWR MOUNT O/B HOLE SPOTFACE THK 0.0464" ACCEPTED PER EN1092-08. REWORKED AREA ETCH & INSP FOUND SATIS PER EN1092-08.