What was found
INSPECTION TYPE:2C 4 RUDDER PEDAL ARM ASSEMBLIES REQUIRE NDT FOR PREVIOUSLY DRILLED LOCK FASTENER HOLES. REMOVED LOCK FASTENER, PERFORMED FP INSPECTION, NO CRACKS NOTED, APPLIED ALODINE TO HOLES, INSTALLED HLT334-6-22 FASTENERS AND HL386-6 COLLARS AND MARKED IAW UPS EO MD11-2720-28975-A AND SAA EA 011-2720-01-A0932 REV A.