What was found
INSPECTION TYPE:C LT WING UPPER STRINGER END NR S12 SUSPECT CRACK AS MARKED THRU ACCESS NR 535BT. HFEC INSP CARRIED OUT PER DAC NDT SPM R.13 PART 06.10.01.00 AND CRACK APPROX 7 INCHES FOUND. CRACK AT LHW STR NR 12 SLOTTED OUT PER SRM 57-20-00 FIG 10 V.1R.35. REPAIR ANGLES FABRICATED PER SRM 57-20-00 FIG 10V.1R.35 AND HEAT TREATED TO T6 PER DPS7.00-1 HARDNESS OBTAINED HRB82.5 IS ACCEPTABLE PER DPS1.05.3. REPAIR ANGLES HOLES PICK UP PER SRM 57-20-00 FIG 10 V.1R.35.