What was found
INSPECTION TYPE:C PYLON NR 2 EXHAUST FAIRING LT FWD SEAL MOUNT 3RD HOLE FROM BOTTOM FOUND ELONGATED AFTER REMOVAL OF SEAL AND RETAINER. DAMAGED AREA TRIMMED OUT PER EN1131-08. HFEC INSP C/OUT PER DAC NDTSPM R.13 06-10-01.001 FOUND NO CRACK EVIDENT. EXTERNAL DOUBLER FABRICATED USING 2219-0 0.071" PER EN1131-08. REP DOUBLER HEAT TREATED TO T62 COND PER DPS7.00-1 HARDNESS OBTAINED HRB64.9 IS ACCEPTABLE PER DPS1.05-3. REPAIR PARTS INSTALLED PER UPS RAA NR MD11-54-20174 AND EN 1131-08.