What was found
INSPECTION TYPE:C CTR CARGO COMPT AT STA 1841, X=-02 & X=-10, WEB FOUND DENTED AS MARKED. DENTED WEB AT STA 1841, RT & ATTACHING FASTENERS REMOVED. NEW WEB FAB USING MAT'L 7075T6 0.050" PER BOEING DWG ACA7170. HOLES PICKED UP & PAINTING DONE ON NEW WEB. NEW WEB INSTALLED PER SRM 51-33-01VIIR35 & FASTENERS RE-INSTALLED PER SRM 51-33-01VIIR35.