What was found
INSPECTION TYPE:2C LEFT FIXED LEADING EDGE RIB STA XORS 917 CRACKED ON LWR FLANGE VIEWED WITH MIRROR. STOP DRILLED CRACK, FABRICATED SHIM AND REPAIR ANGLE IAW MD-11 SRM 57-00-01, 51-21-01, AND DWG ARB2920.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:2C LEFT FIXED LEADING EDGE RIB STA XORS 917 CRACKED ON LWR FLANGE VIEWED WITH MIRROR. STOP DRILLED CRACK, FABRICATED SHIM AND REPAIR ANGLE IAW MD-11 SRM 57-00-01, 51-21-01, AND DWG ARB2920.